EN 50264-3-1 Medium Wall Single Core Unsheathed Cables 0.6/1 kV or 1.8/3 kV
APPLICATIONBRAIL MW-1SU / BRAIL MW-3SU Series Single-Core Unsheathed CablesStrictly compliant with the EN 50264-3-1 standard, the BRAIL MW-1SU/BRAIL MW-3SU series of single-core unsheathed cables are cost-effective power and control cables specificall…
Contact us

APPLICATION

BRAIL MW-1SU / BRAIL MW-3SU Series Single-Core Unsheathed Cables

Strictly compliant with the EN 50264-3-1 standard, the BRAIL MW-1SU/BRAIL MW-3SU series of single-core unsheathed cables are cost-effective power and control cables specifically engineered for the demanding electrical systems of rail vehicles. They are suitable for protective wiring both inside and outside vehicles, particularly in cost-sensitive installations .

This cable series is the ideal choice for wiring control circuits, auxiliary circuits, and main circuits in rolling stock. It reliably serves applications including:

Vehicle wire harness integration

Switchboard/panel connections

Control panel wiring

Driver's console equipment connections

Onboard equipment power transmission

Featuring excellent electrical properties (e.g., voltage rating, current-carrying capacity) and outstanding flame-retardant, low smoke zero halogen (LSZH) characteristics (complying with relevant fire safety standards like EN 45545-2 HL3), the BRAIL MW-1SU/BRAIL MW-3SU cables provide essential assurance for the safe and reliable operation of rail vehicles under demanding conditions. They represent a preferred solution for meeting mandatory rail fire safety regulations such as EN 45545.

CONSTRUCTION

ConductorFlexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
InsulationLSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature90°C ( fixed installation )
Minimum Permissible Ambient Temperature-25°C/-40°C ( fixed installation )
Bending Radius
 
For 0.6/1KV Cables

Fixed installation :

3 x Overall Diameter (D<12mm) ; 4 x Overall Diameter (D>12mm)

Flexible installation :

6 x Overall Diameter (D<12mm)  ; 8 x Overall Diameter (D>12mm)

For 1.8/3KV Cables

Fixed installation :

5 x Overall Diameter (D<12mm) ; 6 x Overall Diameter (D>12mm)

Flexible installation :

10 x Overall Diameter (D<12mm) ; 12 x Overall Diameter (D>12mm)

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ; 
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074; 
NF C 20-454; VDE 0472 Teil 815
Halogen Free

EN 50267-2-2/3; IEC 60754-2; NF C 32-074;

NF C 20-453; VDE 0472 Teil 813

Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index

FRL-MW-1SU 0.6/1 KV

Nominal Cross-Sectional AreaConductor Diameter (a)Min. Mean Thickness of InsulationOverall DiameterWeightConductor ResistanceInsulation Resistance
minmax20℃20℃90℃
mm²mmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
1.01.250.62.42.8102011.40.114
1.51.50.72.83.32013.711.00.110
2.51.950.73.23.8308.219.10.091
42.50.73.84.4505.097.50.075
63.00.74.25.0603.396.50.065
103.90.75.15.91101.955.20.052
165.00.76.17.21601.244.20.042
256.40.97.89.12400.7954.10.041
357.70.99.010.63300.5653.50.035
509.21.010.612.44600.3933.30.033
7011.01.112.514.66600.2773.00.030
9512.51.113.916.38600.2102.70.027
12014.21.215.718.410800.1642.70.027
15015.81.417.620.613700.1322.70.027
18517.51.619.622.916900.1082.60.026
24020.11.722.226.022300.08172.60.026
30022.51.824.628.827800.06542.40.024
40025.82.028.132.937400.04952.40.024

FRL-MW-3SU 1.8/3 KV

Nominal Cross-Sectional AreaConductor Diameter (a)Min. Mean Thickness of InsulationOverall DiameterWeightConductor ResistanceInsulation Resistance
minmax20℃20℃90℃
mm²mmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
1.51.52.05.36.25013.721.00.210
2.51.952.05.76.7608.2118.00.180
42.52.06.27.3805.0915.50.155
63.02.06.77.81003.3913.70.137
103.92.07.58.81501.9511.50.115
165.02.08.610.02201.249.50.095
256.42.09.911.62900.7957.90.079
357.72.011.113.03900.5656.80.068
509.22.012.514.65300.3935.90.059
7011.02.014.216.67200.2775.00.050
9512.52.216.018.79400.2104.50.045
12014.22.217.620.611600.1644.00.040
15015.82.219.122.314400.1323.70.037
18517.52.420.924.417600.1083.40.034
24020.12.423.727.523500.08173.00.030
30022.52.425.630.128200.06542.70.027
40025.82.629.234.237300.04952.40.024

(a) = for information, indicative only