These medium-wall multicore unscreened cables are intended for protected power and control installations in rail and transport vehicles. Their key advantages include cost-effective handling and installation. Typical applications include the internal and external wiring of control systems, auxiliary circuits, and main circuits, such as within cable harnesses, switchboards, control panels, and driver desks.
Conductor | Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5 |
Insulation | LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EI 104) |
Outer Sheath | LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EI 104) |
Nominal Voltage | 300/500 V or 0.6/1 kV |
Maximum Conductor Temperature | 90°C ( fixed installation ) |
Minimum Permissible Ambient Temperature | -25°C/-40°C ( fixed installation ) |
Bending Radius | Fixed installation : 4 x Overall Diameter (D<12mm); 5 x Overall Diameter (D>12mm) Flexible installation : 8 x Overall Diameter (D<12mm); 10 x Overall Diameter (D>12mm) |
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
EN 50306-2 | Hazard levels HL1, HL2, HL3 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN 54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 |
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 | Smoke index |
EN50200: 2000 | Resistance to fire of unprotected small cable for use in emergency circuits 4 classifications are defined: PH 15,30,60, or 90mins; |
IEC60331-21 | The circuit integrity test under fire of cables rated 0.6/1.0kV and below |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
Nominal Cross-Sectional Area (a) | Conductor Diameter (b) | Min. Mean Thickness of Insulation | Core Dimensions | Min. Average Sheath Thickness | Overall Diameter | Weight | Max. Conductor Resistance | Min. Insulation Resistance | |||
---|---|---|---|---|---|---|---|---|---|---|---|
EI 110 | EI 106/7/8/9 | ||||||||||
Min. Acc.to EN | Max. Acc.to EN | Min. | Max. | 20°C | 20°C | 20°C | |||||
n x mm² | mm | mm | mm | mm | mm | mm | mm | kg/km | Ω/km | MΩ x km | MΩ x km |
2 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.6 | 5.3 | 6.2 | 40 | 20.0 | 15.0 | 7.5 |
4 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.6 | 6.1 | 7.2 | 70 | 20.0 | 15.0 | 7.5 |
7 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.7 | 7.5 | 8.7 | 120 | 20.0 | 15.0 | 7.5 |
9 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.7 | 9.1 | 10.6 | 160 | 20.0 | 15.0 | 7.5 |
12 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.7 | 9.8 | 11.5 | 190 | 20.0 | 15.0 | 7.5 |
19 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 0.8 | 11.7 | 13.7 | 290 | 20.0 | 15.0 | 7.5 |
24 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 1.0 | 14.1 | 16.5 | 390 | 20.0 | 15.0 | 7.5 |
32 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 1.0 | 15.5 | 18.2 | 490 | 20.0 | 15.0 | 7.5 |
37 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 1.0 | 16.1 | 18.9 | 550 | 20.0 | 15.0 | 7.5 |
40 x 1 | 1.25 | 0.4 | 2.0 | 2.4 | 1.0 | 16.7 | 19.6 | 600 | 20.0 | 15.0 | 7.5 |
4 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 0.7 | 7.3 | 8.6 | 110 | 13.7 | 14.0 | 7.0 |
7 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 0.7 | 8.7 | 10.2 | 170 | 13.7 | 14.0 | 7.0 |
9 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 0.8 | 10.9 | 12.7 | 230 | 13.7 | 14.0 | 7.0 |
12 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 0.8 | 11.8 | 13.8 | 280 | 13.7 | 14.0 | 7.0 |
19 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 1.0 | 14.2 | 16.6 | 440 | 13.7 | 14.0 | 7.0 |
24 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 1.0 | 16.6 | 19.5 | 560 | 13.7 | 14.0 | 7.0 |
32 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 1.2 | 18.7 | 21.9 | 720 | 13.7 | 14.0 | 7.0 |
37 x 1.5 | 1.5 | 0.5 | 2.4 | 2.9 | 1.2 | 19.5 | 22.8 | 820 | 13.7 | 14.0 | 7.0 |
4 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 0.7 | 8.3 | 9.8 | 150 | 8.21 | 13.0 | 6.5 |
7 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 0.8 | 10.2 | 11.9 | 240 | 8.21 | 13.0 | 6.5 |
9 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 1.0 | 12.9 | 15.1 | 350 | 8.21 | 13.0 | 6.5 |
12 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 1.0 | 13.9 | 16.3 | 420 | 8.21 | 13.0 | 6.5 |
19 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 1.0 | 16.3 | 19.1 | 640 | 8.21 | 13.0 | 6.5 |
24 x 2.5 | 1.95 | 0.5 | 2.9 | 3.4 | 1.2 | 19.6 | 22.9 | 840 | 8.21 | 13.0 | 6.5 |
(a)= One earth conductor (green/yellow) can be included upon request
(b)= For information, indicative only
Nominal Cross-Sectional Area (a) | Conductor Diameter (b) | Min. Mean Thickness of Insulation | Core Dimensions | Min. Average Sheath Thickness | Overall Diameter | Weight | Max. Conductor Resistance | Min. Insulation Resistance | |||
---|---|---|---|---|---|---|---|---|---|---|---|
EI 110 | EI 106/7/8/9 | ||||||||||
Min. Acc.to EN | Max. Acc.to EN | Min. | Max. | 20°C | 20°C | 20°C | |||||
n x mm² | mm | mm | mm | mm | mm | mm | mm | kg/km | Ω/km | MΩ x km | MΩ x km |
TWO CORES | |||||||||||
1.5 | 1.5 | 0.7 | 2.8 | 3.3 | 0.70 | 7.2 | 9.0 | 70 | 13.7 | 21.0 | 10.5 |
2.5 | 1.95 | 0.7 | 3.2 | 3.8 | 0.70 | 8.0 | 10.0 | 100 | 8.21 | 17.2 | 8.6 |
4 | 2.5 | 0.7 | 3.8 | 4.4 | 0.70 | 9.1 | 11.3 | 130 | 5.09 | 14.2 | 7.1 |
6 | 3.0 | 0.7 | 4.2 | 5.0 | 0.80 | 10.1 | 12.4 | 170 | 3.39 | 12.2 | 6.1 |
10 | 3.9 | 0.7 | 5.1 | 5.9 | 1.00 | 12.5 | 15.4 | 290 | 1.95 | 9.8 | 4.9 |
16 | 5.0 | 0.7 | 6.1 | 7.2 | 1.00 | 14.9 | 18.4 | 390 | 1.24 | 7.9 | 3.9 |
25 | 6.4 | 0.9 | 7.8 | 9.1 | 1.20 | 18.7 | 23.0 | 590 | 0.795 | 7.3 | 3.6 |
35 | 7.7 | 0.9 | 9.0 | 10.6 | 1.20 | 21.2 | 25.9 | 790 | 0.565 | 6.7 | 3.3 |
50 | 9.2 | 1.0 | 10.6 | 12.4 | 1.40 | 25.1 | 30.7 | 1140 | 0.393 | 6.3 | 3.1 |
THREE CORES | |||||||||||
1.5 | 1.5 | 0.7 | 2.8 | 3.3 | 0.70 | 7.7 | 9.5 | 100 | 13.7 | 21.0 | 10.5 |
2.5 | 1.95 | 0.7 | 3.2 | 3.8 | 0.70 | 8.5 | 10.5 | 130 | 8.21 | 17.2 | 8.6 |
4 | 2.5 | 0.7 | 3.8 | 4.4 | 0.70 | 9.7 | 12.0 | 180 | 5.09 | 14.2 | 7.1 |
6 | 3.0 | 0.7 | 4.2 | 5.0 | 0.80 | 10.7 | 13.2 | 250 | 3.39 | 12.2 | 6.1 |
10 | 3.9 | 0.7 | 5.1 | 5.9 | 1.00 | 13.3 | 16.5 | 410 | 1.95 | 9.8 | 4.9 |
16 | 5.0 | 0.7 | 6.1 | 7.2 | 1.00 | 16.0 | 19.6 | 570 | 1.24 | 7.9 | 3.9 |
25 | 6.4 | 0.9 | 7.8 | 9.1 | 1.20 | 20.0 | 24.7 | 850 | 0.795 | 7.3 | 3.6 |
35 | 7.7 | 0.9 | 9.0 | 10.6 | 1.40 | 23.0 | 28.2 | 1160 | 0.565 | 6.7 | 3.3 |
50 | 9.2 | 1.0 | 10.6 | 12.4 | 1.60 | 26.3 | 32.2 | 1680 | 0.393 | 6.3 | 3.1 |
FOUR CORES | |||||||||||
1.5 | 1.5 | 0.7 | 2.8 | 3.3 | 0.70 | 8.5 | 10.5 | 120 | 13.7 | 21.0 | 10.5 |
2.5 | 1.95 | 0.7 | 3.2 | 3.8 | 0.70 | 9.4 | 11.6 | 170 | 8.21 | 17.2 | 8.6 |
4 | 2.5 | 0.7 | 3.8 | 4.4 | 0.80 | 10.9 | 13.4 | 240 | 5.09 | 14.2 | 7.1 |
6 | 3.0 | 0.7 | 4.2 | 5.0 | 1.00 | 12.2 | 14.9 | 330 | 3.39 | 12.2 | 6.1 |
10 | 3.9 | 0.7 | 5.1 | 5.9 | 1.00 | 14.7 | 18.2 | 540 | 1.95 | 9.8 | 4.9 |
16 | 5.0 | 0.7 | 6.1 | 7.2 | 1.20 | 18.0 | 22.1 | 750 | 1.24 | 7.9 | 3.9 |
25 | 6.4 | 0.9 | 7.8 | 9.1 | 1.40 | 22.6 | 27.6 | 1140 | 0.795 | 7.3 | 3.6 |
3 x 35+25 | 7.7/6.4 | 0.9/0.9 | 9.0/7.8 | 10.6/9.1 | 1.40 | 25.7 | 31.2 | 1490 | 0.565/0.795 | 6.7 | 3.3 |
3 x 50+25 | 9.2/6.4 | 1.0/0.9 | 10.6/7.8 | 12.4/9.1 | 1.60 | 30.0 | 36.5 | 2110 | 0.393/1.795 | 6.3 | 3.1 |
(a)= One earth conductor (green/yellow) can be included upon request
(b)= For information, indicative only