Signal and Control Cable BRAIL TW-05MP-ESW-IOS - Made for Rail Transit, Optimized for Space and Weight
Made for the demanding environment of rail transit! The BRAIL TW-05MP-ESW-IOS Signal and Control Cable is the ideal cabling solution for onboard and wayside signal transmission and control systems. It excels particularly in space-constrained and weight-sensitive applications.
Conductor | Tinned annealed copper wires as defined in EN 50306-2 |
Insulation | LSZH special compound |
Overal screen | Tinned annealed copper wires |
Pair screen | Individual screened and sheathed. Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1, S2) |
Pair Identification | Pairs numbered according to EN 50306-4 |
Outer sheath | LSZH special compound (S2, EM 101 - EM 104) |
|
A. Conductor B. Insulation C. Screen D.Sheath |
Nominal Voltage | 300/500 V |
Maximum Conductor Temperature | 90°C /105°C (fixed installation) |
Minimum Permissible Ambient Temperature | -25/-40°C (fixed installation) |
Bending Radius | 10 x Overall Diameter |
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
EN 50306-2 | Hazard levels HL1, HL2/HL3, HL4 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN45545-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 |
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
Number of Cores and Nominal Cross Section | Minimum Thickness of Sheath at any Point | Overall Diameter | Weight | |
min. | max. | |||
n x mm2 | mm | mm | mm | kg/km |
2 x 2 x 0.5 | 1.0 | 10.1 | 11.3 | 100 |
3 x 2 x 0.5 | 1.0 | 10.8 | 12.0 | 150 |
4 x 2 x 0.5 | 1.0 | 11.8 | 13.0 | 180 |
7 x 2 x 0.5 | 1.0 | 13.9 | 15.5 | 270 |
2 x 2 x 0.75 | 1.0 | 10.9 | 12.1 | 120 |
3 x 2 x 0.75 | 1.0 | 11.6 | 12.8 | 170 |
4 x 2 x 0.75 | 1.0 | 12.8 | 14.0 | 220 |
7 x 2 x 0.75 | 1.0 | 15.1 | 16.7 | 330 |
2 x 2 x 1.0 | 1.0 | 11.3 | 12.5 | 130 |
3 x 2 x 1.0 | 1.0 | 12.0 | 13.2 | 190 |
4 x 2 x 1.0 | 1.0 | 13.2 | 14.4 | 235 |
7 x 2 x 1.0 | 1.0 | 15.7 | 17.3 | 370 |
2 x 2 x 1.5 | 1.0 | 13.3 | 14.5 | 180 |
3 x 2 x 1.5 | 1.0 | 14.0 | 15.6 | 260 |
4 x 2 x 1.5 | 1.0 | 15.5 | 17.1 | 340 |
7 x 2 x 1.5 | 1.0 | 18.7 | 20.3 | 540 |