Flame Retardant CAT5E CWB/SWB/SWA Armoured Data Cables
APPLICATIONCat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer s…
Flame Retardant CAT5e CWB_SWB_SWA Armoured Data Cables.pdf Contact us

APPLICATION

Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

STANDARDS

ISO/IEC 11801 , EN 50173 , ANSI/TIA/EIA 568

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test) :BS EN 60332-1-2

CABLE CONSTRUCTION

Conductor : 24AWG solid bare copper.

Insulation : PE.

Twinning : Two coloured insulated conductors twisted together to form a pair.

Inner Sheath : Flame retardant, low smoke and halogen-free polyolefin, coloured black.

Armouring :

CWB : Copper Wire Braid

SWB : Steel Wire Braid

SWA : Steel Wire Armour

Outer Sheath : Thermoplastic PVC compound.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

Cat5EF/UTP : These cables have collective shielding of Aluminium/polyester tape with drain wire.

Cat5ESF/UTP : These cables have double collective shielding of Aluminium/polyester tape & copper wire braid.

PHYSICAL AND THERMAL PROPERTIES

Temperature range : -30°C - +75°C

Minimum bending radius during installation (mobile state) : 8 x Overall Diameter

Minimum bending radius during operation (fixed state) : 4 x Overall Diameter

ELECTRICAL PROPERTIES

AWG
24
Nominal Conductor Diametermm0.50/0.51/0.53
Maximum DC Resistance@20°CΩ/100m9.38
Maximum DCR Unbalance%5
Maximum Mutual CapacitancepF/m55.8
Maximum Capacitance UnbalancepF/100m330
Characteristic Impedance@1-100MHzΩ100±15
Maximum Propagation Delay Skewns/100m45

TRANSMISSION PROPERTIES

FREQAttenuationNEXTPSNEXTELFEXTPSELFEXTRL
MHzdB/100mdBdBdB/100mdB/100mdB
0.7721.867.064.066.063.0
12.065.362.363.860.820.2
44.156.353.351.748.723.0
85.851.848.845.742.724.5
106.550.347.343.840.825.0
168.247.344.339.736.725.0
209.345.842.837.734.725.0
2510.444.341.335.832.824.3
31.2511.742.939.933.930.923.6
62.517.038.435.427.824.821.5
10022.035.332.323.820.820.1

CONSTRUCTION PARAMETERS

Cable CodeConstruction No. of Elements×No. of Cores in Element×Conductor DiameterNominal Insulation ThicknessNominal Inner Sheath ThicknessNominal Outer Sheath ThicknessApprox. Overall DiameterNominal Weight
mmmmmmmmmmkg/km
FLP-CAT5EU/UTP4P24 CWB4×2×0.50.20.61.07.6897
FLP-CAT5EU/UTP4P24 SWB4×2×0.50.20.61.07.6893
FLP-CAT5EU/UTP4P24 SWA4×2×0.50.20.61.08.68165
FLP-CAT5EF/UTP4P24 CWB4×2×0.530.20.61.08.28116
FLP-CAT5EF/UTP4P24 SWB4×2×0.530.20.61.08.28112
FLP-CAT5EF/UTP4P24 SWA4×2×0.530.20.61.09.28192
FLP-CAT5ESF/UTP4P24 CWB4×2×0.530.20.61.08.76123
FLP-CAT5ESF/UTP4P24 SWB4×2×0.530.20.61.08.76119
FLP-CAT5ESF/UTP4P24 SWA4×2×0.530.20.61.09.76216