whatsapp
backtop
ProfiNet Type A Radiation Resistant & Armored
APPLICATION AND DESCRIPTIONIndustrial Ethernet ProfiNet cables are designed to provide reliable network communications in the demanding Industrial and Process Control environment where difficult EMC conditions are pervasive. Conforming to the EIA/TIA-…
ProfiNet Type A Radiation Resistant &.pdf Contact us

APPLICATION AND DESCRIPTION

Industrial Ethernet ProfiNet cables are designed to provide reliable network communications in the demanding Industrial and Process Control environment where difficult EMC conditions are pervasive. Conforming to the EIA/TIA-568 standard, These Cables support half-duplex high speed communications.It ensures superior transmission properties and can be used even under most severe conditions.

CONSTRUCTION

Type/Area of ApplicationRay loaded areasFixed Installation, Outdoor
Cable Construction2x2x0.64 mm2x2x0.64 mm
Inner Conductor DiameterCopper, bare (AWG 22/1)Copper, bare (AWG 22/1)
Conductor InsulationXLPE ray cross-linkingPE
Conductor Colorswhite, yellow, blue, orangewhite, yellow, blue, orange
Stranding ElementStar quadStar quad
WrappingPolyester foil over stranded bundlePolyester foil over stranded bundle
ShieldingPolyester foil, aluminum-linedPolyester foil, aluminum-lined
Total ShieldingCu braid, tinnedCu braid, tinned
Armoring-Steel Rib
Inner Jacket MaterialTPR cross-linkingPVC
Outer Jacket MaterialPURPE
Outer Diameter6.5 mm ± 0.2 mm9.3 mm ± 0.5 mm
Outer Jacket ColorGreenBlack

ELECTRICAL DATA

Characteristic Impedance@1-100 MHz100 Ω ± 15 Ω
Conductor Resistance62.0 Ohm/km max.
Insulation Resistance0.50 GOhm x km min.
Mutual Capacitance50.0 nF/km nom.
Working Voltage300V
Test Voltage1.5 KV

10 MHz5.2 dB/100m
Attenuation16 MHz6.9 dB/100m

62.5 MHz16.0 dB/100m

100 MHz19.5 dB/100m

TECHNICAL DATA

Weightapproximately 63.0 kg/kmapproximately 124.0 kg/km
Min. Bending Radius (Laying)46.0 mm93.0 mm
Operating Temp. Range, min.-40 °C-40 °C
Operating Temp.Range, max.+80 °C+70 °C