Individual & Overall Screened Thermocouple Cable
Individual & Overall Screened Thermocouple CableApplicationsThese cables are used with thermocouples for temperature measurements where hydrocarbon may be present.StandardsIEC 60584-3NF C 42-324ConstructionConductor : Metal according to thermocoup…
Individual & Overall Screened Thermocouple Cable.pdf Contact us

Individual & Overall Screened Thermocouple Cable

Applications

These cables are used with thermocouples for temperature measurements where hydrocarbon may be present.

Standards

IEC 60584-3

NF C 42-324

Construction

Conductor : Metal according to thermocouple type

Insulation : PVC

Individual screen : Aluminum/polyester tape with tinned copper drain wire

Individual sheath : PVC

Overall screen : Aluminum/polyester tape with tinned copper drain wire

Sheath : Special PVC. Color depends on thermocouple type

Properties

Flame retardance : NFC 32070 C2, IEC 60332-1-2

Operating voltage : 250V

Operating temperature : -20~60°C

Max. conductor temperature in service : 70°C

Chemical resistance: Aliphatic and aromatic hydrocarbon resistance

Conductor SizeNo. of PairsMin. O.D.Max. O.D.Approx. Weight
mm² mmmmkg/km
0.5 solid311.112.8180
0.5 solid715.417.7335
0.5 solid1219.822.8545
0.5 solid1924.628.1825
0.5 solid2728.933.21135