H01N2-D-E to BS 638-4
Application and DescriptionThese cables are used as a connection between the welding generator, the hand-electrode and the work piece, they are suitable for use in the automobile industry, ship building, transport and conveyor systems, tool making mac…
H01N2-D-E to BS 638-4(New BS EN50525-2-81.pdf Contact us

Application and Description

These cables are used as a connection between the welding generator, the hand-electrode and the work piece, they are suitable for use in the automobile industry, ship building, transport and conveyor systems, tool making machinery, welding robots etc. These cables retain their high flexibility even under influence of ozone, light, oxygen, protective gases, oil and petrol. Robust design of these cables makes them resistant to low and high temperature, fire, ozone and radiation, oils, acids, fats and petrols. These cables are also ideal for outside installation in dry, moist and wet areas.

Cable Construction

  • - Extra fine bare copper strands

  • - Stranding to BS 6360 CL-5/6, IEC 60228 CL-5/6

  • - Synthetic or paper separator over core

  • - Chlorosulphonated Polyethylene (C.S.P.), HOFR (Heat and Oil Resistant and Flame Retardant) to
    BS7655 , black/ orange

Technical Characteristics

  • - Working voltage: 100/100 volts

  • - Test voltage: 1000 volts

  • - Minimum bending radius: 12.0xOverall diameter (H01N2-D)
    10xOverall diameter (H01N2-E)

  • - Flexing Temperature: -25o C to +80o C

  • - Fixed Temperature: -40o C to +80o C

  • - Flame retardant: IEC 60332.1

Cable Parameter

H01N2-D (standard flexibility)

AWG
(No of Strands/
Strand Diameter)
No. of Cores x
Nominal Cross
Sectional Area
#xmm^2
Nominal
Thickness of
Insulation
mm
Nominal
Overall
Diameter
mm
Nominal
Copper
Weight
kg/km
Nominal
Weight
kg/km
8(320/32)1x102.07.7-9.796135
6(512/32)1x162.08.8-11.0154205
4(800/32)1x252.010.1-12.7240302
2(1120/32)1x352.011.4-14.2336420
1(1600/32)1x502.213.2-16.5480586
2/0(2240/32)1x702.415.3-19.2672798
3/0(3024/32)1x952.617.1-21.49121015
4/0(614/24)1x1202.819.2-2411521310
300MCM(765/24)1x1503.021.2-26.414401620
350MCM(944/24)1x1853.223.1-28.917761916
500MCM(1225/24)1x2403.425-29.523042540

H01N2-E(high flexibility)

AWG
(No of Strands/
Strand Diameter)
No. of Cores x
Nominal Cross
Sectional Area
#xmm^2
Nominal
Thickness of
Insulation
mm
Nominal
Overall
Diameter
mm
Nominal
Copper
Weight
kg/km
Nominal
Weight
kg/km
8(566/35)1x101.26.2-7.896119
6(903/35)1x161.27.3-9.1154181
4(1407/35)1x251.28.6-10.8240270
2(1974/35)1x351.29.8-12.3336363
1(2830/35)1x501.511.9-14.8480528
2/0(3952/35)1x701.813.6-17.0672716
3/0(5370/35)1x951.815.6-19.59121012
4/0(3819/32)1x1201.817.2-21.611521190
300MCM(4788/32)1x1501.818.8-23.514401305
500MCM(5852/32)1x1851.820.4-25.517761511