6241B/6242B/ 6243B to BS 7211
Application and DescriptionThese cables are suitable for fixed installation particularly for situations in which low emission smoke and domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes cre…
6241B-6242B-6243B to BS 7211.pdf Contact us

Application and Description

These cables are suitable for fixed installation particularly for situations in which low emission smoke and domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises on walls, boards or trays, in channels or embedded in plaster. Suitable for laying in conduit or trunking where mechanical protection is required.

Cable Construction

  • - Fine bare copper strands

  • - Stranding to IEC 60228 CL-1 or 2

  • - Thermosetting core insulation type EI5 or GP 8

  • - The core or cores shall be laid parallel with the uninsulated circuit protective conductor

  • - For twin cores, the protective conductor centrally placed between cores in same plane

  • - For 3 cores, the protective conductor centrally placed between black and grey cores in same plane

  • - LSOH sheath, type LTS 2, white

Core Identification

  • 2 cores: brown and blue, or, for 2 × 1.0 and 2 × 1.5 cables, brown and brown

  • 3 cores: brown, black (centre core) and grey

Technical Characteristics

  • - Working voltage: 300/500 volts

  • - Test voltage: 2000 volts

  • - Flexing bending radius: 15xOverall diameter

  • - Static bending radius: 10xOverall diameter

  • - Flexing temperature: +5o C to +90o C

  • - Short circuit temperature: +250o C

  • - Insulation resistance: 10 MΩxkm

  • - Halogen free acc. to EN 50267-2-1 / IEC 60754-1

  • - Smoke density acc. to EN 50268-2 / IEC 61034-2

  • - Corrosivity of gases acc. to EN 50267-2-2, IEC 60754-2

  • - Flame retardancy acc. to EN 50265-2-1, IEC 60332-1

Cable Parameter

AWG
(No of Strands/
Strand Diameter)
No. of Cores x
Nominal Cross
Sectional Area
#xmm^2
Nominal
Thickness of
Insulation
mm
Nominal
Thickness of
Sheath
mm
Nominal overall
dimensions
Circuit
protective
conductor
AWG
Nominal
Weight
kg/km
lower limit
mm
upper limit
mm
6241B
171 × 1.00.70.94.1 × 5.25.0 × 6.31745
161 × 1.50.70.94.4 × 5.45.3 × 6.61755
6242B
172 × 1.00.70.94.1 × 7.65.0 × 9.11768
17(7/26)2 × 1.00.70.94.2 × 7.85.1 × 9.41773
162 × 1.50.70.94.4 × 8.15.3 × 9.71785
16(7/24)2 × 1.50.70.94.5 × 8.35.4 × 101790
142 × 2.50.71.04.9 × 9.36 × 11.216120
14(7/22)2 × 2.50.71.05.0 × 9.56.1 × 11.416125
12(7/20)2 × 40.71.05.5 × 10.46.7 × 12.616175
10(7/18)2 × 60.71.16.2 × 12.07.5 × 14.614240
8(7/16)2 × 100.71.27.3 × 14.58.8 × 17.612(7/20)390
6(7/14)2 × 160.71.38.4 × 17.010.1 × 20.510(7/18)560
6243B
173 × 1.00.70.94.1 × 105.1 × 12.11791
163 × 1.50.70.94.4 × 10.75.3 × 12.917115
143 × 2.50.71.04.9 × 12.06 × 14.617170
12(7/20)3 × 40.71.05.5 × 146.7 × 16.916196
10(7/18)3 × 60.71.16.2 × 16.27.5 × 19.514291
8(7/16)3 × 100.71.27.3 × 19.58.8 × 23.612(7/20)440
6(7/14)3 × 160.71.38.4 × 22.810.1 × 27.610(7/18)670