RE-2Y(St)HSWAH PIMF
PE Insulated, LSZH Sheathed, Individual and Overall Screened & Armoured Instrumentation Cables (Multipair)ApplicationThe armoured LSZH sheathed cables are generally used when the risk of mechanical damage is increased. The galvanized steel wire ar…
RE-2Y(St)HSWAH PIMF.pdf Contact us

PE Insulated, LSZH Sheathed, Individual and Overall Screened & Armoured Instrumentation Cables (Multipair)

Application

The armoured LSZH sheathed cables are generally used when the risk of mechanical damage is increased. The galvanized steel wire armour provides excellent protection. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for theinterconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.

Standards

Basic design to EN 50288-7

Fire Performance

Flame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation(Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gasesNES 02-713; NF C 20-454
Sunlight ResistanceUL 1581 section 1200
Oil ResistanceICEA S-73-532**

Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.

Voltage Rating

300V

Cable Construction

  • Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2.

  • Insulation: PE compound, EN 50290. 2-23.

  • Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

  • Individual Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2

  • Binder tape: PETP transparent tape

  • Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2

  • Inner Sheath: LSZH(Low Smoke Zero Halogen) sheath

  • Amouring: Galvanized steel wire armour

  • Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

Colour Code

  • Insulation: Black / White, continuously numbered on white core(1, 2..)for multipair.

  • Outer Sheath:  Black or Blue for intrinsically safe systems

Physical and Thermal Properties

  • Temperature Range During Operation (Fixed State): -30°C – +90°C

  • Temperature Range During Installation (Mobile State): -20°C – +50°C

  • Minimum Bending Radius:10 X Overall Diameter

Electrical Roperties

Conductor Area Sizemm20.50.751.01.31.5
Insulation thickness (nominal)mm0.40.40.40.450.45
Conductor resistance (20°C)Ω/km36.72518.514.212.3
Insulation resistance (20°C)MΩ.km(Min.)5000
Mutual Capacitance (1 kHz)pF/m(Max.)115
InductancemH/km (Max.)1
L / R (ratio) (max.)μH/Ω2525254040
Operating voltage UrmsV300
Test VoltageCore to CoreV1500
Core to ScreenV1500

Construction Parameterst

Caledonian Cable CodeRE-2X(St)HSWAH PiMF
No. of Pairsx2 xCross SectionNominal Insulation Thick -nessNominal Inner Sheath Thick -nessNominal Overall Diameter Over InnerSheathNominal Armour Wire DiameterNominal Outer Sheath Thick -nessNominal Overall DiameterApprox. Weight
No.x2xmm2mmmmmmmmmmmmkg/km
0.5mm2, Multipair
RE-2X(St)HSWAH PiMF 2P0.52x2x0.50.350.98.70.91.413.3311
RE-2X(St)HSWAH PiMF 4P0.54x2x0.50.351.010.20.91.414.8374
RE-2X(St)HSWAH PiMF 5P0.55x2x0.50.351.011.20.91.415.8451
RE-2X(St)HSWAH PiMF 6P0.56x2x0.50.351.012.10.91.616.9484
RE-2X(St)HSWAH PiMF 8P0.58x2x0.50.351.113.10.91.617.9563
RE-2X(St)HSWAH PiMF 10P0.510x2x0.50.351.215.10.91.519.9782
RE-2X(St)HSWAH PiMF 12P0.512x2x0.50.351.215.70.91.520.5804
RE-2X(St)HSWAH PiMF 16P0.516x2x0.50.351.217.81.251.623.5970
RE-2X(St)HSWAH PiMF 20P0.520x2x0.50.351.319.71.251.725.61145
RE-2X(St)HSWAH PiMF 24P0.524x2x0.50.351.421.51.251.727.41272
0.75mm2, Multipair
RE-2X(St)HSWAH PiMF 2P0.752x2x0.750.381.09.70.91.414.3342
RE-2X(St)HSWAH PiMF 4P0.753x2x0.750.381.011.20.91.415.8439
RE-2X(St)HSWAH PiMF 5P0.754x2x0.750.381.112.50.91.517.3498
RE-2X(St)HSWAH PiMF 6P0.755x2x0.750.381.113.60.91.518.4565
RE-2X(St)HSWAH PiMF 8P0.758x2x0.750.381.114.40.91.519.2639
RE-2X(St)HSWAH PiMF 10P0.7510x2x0.750.381.216.61.251.622.3878
RE-2X(St)HSWAH PiMF 12P0.7512x2x0.750.381.217.41.251.623.1944
RE-2X(St)HSWAH PiMF 16P0.7516x2x0.750.381.319.81.251.725.71132
RE-2X(St)HSWAH PiMF 20P0.7520x2x0.750.381.422.01.251.727.91329
RE-2X(St)HSWAH PiMF 24P0.7524x2x0.750.381.524.01.251.830.11488
1.0mm2, Multipair
RE-2X(St)HSWAH PiMF 2P1.02x2x1.00.41.010.40.91.415.0377
RE-2X(St)HSWAH PiMF 4P1.03x2x1.00.41.012.10.91.416.7502
RE-2X(St)HSWAH PiMF 5P1.04x2x1.00.41.113.50.91.518.3567
RE-2X(St)HSWAH PiMF 6P1.05x2x1.00.41.114.70.91.519.5658
RE-2X(St)HSWAH PiMF 8P1.08x2x1.00.41.215.80.91.520.6865
RE-2X(St)HSWAH PiMF 10P1.010x2x1.00.41.218.01.251.623.7994
RE-2X(St)HSWAH PiMF 12P1.012x2x1.00.41.319.01.251.724.71112
RE-2X(St)HSWAH PiMF 16P1.016x2x1.00.41.321.51.251.727.41363
RE-2X(St)HSWAH PiMF 20P1.020x2x1.00.41.423.91.251.729.81512
RE-2X(St)HSWAH PiMF 24P1.024x2x1.00.41.526.11.251.832.21996
1.3mm2, Multipair
RE-2X(St)HSWAH PiMF 2P1.32x2x1.30.451.011.40.91.416.0452
RE-2X(St)HSWAH PiMF 4P1.33x2x1.30.451.113.40.91.518.2577
RE-2X(St)HSWAH PiMF 5P1.34x2x1.30.451.114.80.91.519.6647
RE-2X(St)HSWAH PiMF 6P1.35x2x1.30.451.216.30.91.621.3858
RE-2X(St)HSWAH PiMF 8P1.38x2x1.30.451.317.61.251.623.3982
RE-2X(St)HSWAH PiMF 10P1.310x2x1.30.451.320.01.251.725.91153
RE-2X(St)HSWAH PiMF 12P1.312x2x1.30.451.421.11.251.727.01287
RE-2X(St)HSWAH PiMF 16P1.316x2x1.30.451.524.11.251.830.21564
RE-2X(St)HSWAH PiMF 20P1.320x2x1.30.451.626.81.251.933.11960
RE-2X(St)HSWAH PiMF 24P1.324x2x1.30.451.729.21.252.036.42356
1.5mm2, Multipair
RE-2X(St)HSWAH PiMF 2P1.52x2x1.50.451.011.80.91.516.6475
RE-2X(St)HSWAH PiMF 4P1.53x2x1.50.451.113.90.91.518.7616
RE-2X(St)HSWAH PiMF 5P1.54x2x1.50.451.215.50.91.520.3819
RE-2X(St)HSWAH PiMF 6P1.55x2x1.50.451.216.91.251.622.6941
RE-2X(St)HSWAH PiMF 8P1.58x2x1.50.451.318.21.251.724.11039
RE-2X(St)HSWAH PiMF 10P1.510x2x1.50.451.421.01.251.726.91242
RE-2X(St)HSWAH PiMF 12P1.512x2x1.50.451.421.91.251.727.81387
RE-2X(St)HSWAH PiMF 16P1.516x2x1.50.451.525.11.251.831.21935
RE-2X(St)HSWAH PiMF 20P1.520x2x1.50.451.627.81.251.934.82227
RE-2X(St)HSWAH PiMF 24P1.524x2x1.50.451.730.41.252.037.62545