LSZH Flame Retardant RS 485 Databus Cables
APPLICATIONThe cables are designed for RS 485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interfe…
LSZH Flame Retardant RS 485 Databus Cables.pdf Contact us

APPLICATION

The cables are designed for RS 485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

STANDARDS

Basic design adapted to EIA/TIA 485

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

CABLE CONSTRUCTION

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors : Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation : Foam PE or foam skin PE.

Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling : Pairs are cabled together in concentric layers.

Overall Screen : Aluminum/polyester tape with tinned copper drain wire.

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

MULTIPAIR RS 485 OVERALL DOUBLE SCREENED DATABUS CABLE

Conductors : Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation : Foam PE or foam skin PE.

Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling : Pairs are cabled together in concentric layers.

Overall Screen : Aluminium/polyester tape+copper wire braid.

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

MULTIPAIR RS 485 INDIVIDUAL & OVERALL SCREENED DATABUS CABLE

Conductors : Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation : Foam PE or foam skin PE.

Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling : Pairs are cabled together in concentric layers.

Individual Screen : Individual aluminium/polyester tape.

Overall Screen : Copper wire braid.

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors : Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation : Foam PE or foam skin PE.

Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.

Cabling : Pairs are cabled together in concentric layers.

Overall Screen : Copper wire braid.

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

PHYSICAL AND THERMAL PROPERTIES

Temperature range during operation (fixed state) : -20°C - +90°C

Temperature range during installation (mobile state) : -5°C - +60°C

Minimum bending radius : 8 x Overall Diameter

ELECTRICAL PROPERTIES

Dielectric test1000 V r.m.s. for 5’ (core-core)
1000 V r.m.s. for 5’ (core-screen)
Impedance120Ω
Capacitance45 nF/km conductor to conductor
90 nF/km conductor to shield

CONSTRUCTION PARAMETERS

Multipair RS 485 Overall Screened Databus Cable

RE-02Y(St)H / RE-02YS(St)H

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm²No/mmmmmmmmkg/km
10.227/0.20.71.15.745
20.227/0.20.71.19.080
40.227/0.20.71.110.3112
10.5016/0.20.71.16.257
20.5016/0.20.71.110.1103
40.5016/0.20.71.111.7153
10.7524/0.20.71.16.766
20.7524/0.20.71.110.9123
40.7524/0.20.71.112.7187
11.0030/0.20.71.16.872
21.0030/0.20.71.111.2131
41.0030/0.20.71.113.0203

Multipair RS 485 Overall Double Screened Databus Cable

RE-02Y(St)CH / RE-02YS(St)CH

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm²No/mmmmmmmmkg/km
10.227/0.20.71.16.260
20.227/0.20.71.19.4105
40.227/0.20.71.110.8142
10.5016/0.20.71.16.774
20.5016/0.20.71.110.6133
40.5016/0.20.71.112.1187
10.7524/0.20.71.17.185
20.7524/0.20.71.111.4155
40.7524/0.20.71.113.2225
11.0030/0.20.71.17.391
21.0030/0.20.71.111.7164
41.0030/0.20.71.113.5242

Multipair RS 485 Individual & Overall Screened Databus Cable

RE-02Y(St)CH PiMF / RE-02YS(St)CH PiMF

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm²No/mmmmmmmmkg/km
10.227/0.20.71.16.461
20.227/0.20.71.110.2110
40.227/0.20.71.111.7149
10.5016/0.20.71.17.075
20.5016/0.20.71.111.4137
40.5016/0.20.71.113.2195
10.7524/0.20.71.17.586
20.7524/0.20.71.112.3160
40.7524/0.20.71.114.3233
11.0030/0.20.71.17.692
21.0030/0.20.71.112.6169
41.0030/0.20.71.114.7251

Multipair RS 485 Overall Screened Databus Cable

RE-02YCH / RE-02YSCH

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm²No/mmmmmmmmkg/km
10.227/0.20.71.16.056
20.227/0.20.71.19.299
40.227/0.20.71.110.6134
10.5016/0.20.71.16.569
20.5016/0.20.71.110.4125
40.5016/0.20.71.112.0179
10.7524/0.20.71.16.980
20.7524/0.20.71.111.2147
40.7524/0.20.71.113.0216
11.0030/0.20.71.17.186
21.0030/0.20.71.111.5156
41.0030/0.20.71.113.3233