BS 6387 CWZ fire resistant cables are essential components in safety-critical systems such as fire alarms, emergency lighting, and life-safety circuits. This article explores the evolution of the BS 6387 standard, comparing the 1994 and 2013 versions, and highlighting the importance of CWZ classification for high-performance fire resistant cables.
BS 6387 is a British Standard that specifies the performance requirements for cables required to maintain circuit integrity under fire conditions. It outlines test methods to assess a cable's ability to continue functioning during and after exposure to fire, water, and mechanical shock. This standard is crucial for ensuring the reliability of cables used in emergency systems, such as fire alarms, emergency lighting, and life safety circuits.
The BS 6387 standard encompasses three primary tests, each simulating different adverse conditions:
Objective: Assess the cable's ability to maintain circuit integrity when exposed to fire.
Test Conditions: The cable is subjected to a flame at 950°C for 3 hours while carrying its rated voltage.
Pass Criteria: The cable must continue to operate without electrical failure throughout the test duration.
Objective: Evaluate the cable's performance under fire conditions combined with water exposure, simulating sprinkler activation.
Test Conditions: The cable is exposed to a flame at 650°C for 15 minutes, followed by simultaneous application of water spray and flame for an additional 15 minutes.
Pass Criteria: Continuous operation without electrical failure during the entire 30-minute test.
Objective: Determine the cable's resilience to mechanical impacts during a fire, replicating structural collapses or impacts.
Test Conditions: The cable is mounted on a backing panel in an S-bend configuration and exposed to a flame at 950°C for 15 minutes. Simultaneously, the backing panel is struck with a steel bar of the same diameter as the cable every 30 seconds.
Pass Criteria: The cable must maintain circuit integrity throughout the test without electrical failure.
A cable that successfully passes all three tests—Categories C, W, and Z—is classified as CWZ, indicating the highest level of fire resistance as per BS 6387. This classification ensures that the cable can withstand fire, water, and mechanical shocks simultaneously, making it suitable for critical applications where maintaining circuit integrity during emergencies is paramount.
The 1994 edition of BS 6387 included multiple test categories, such as A, B, C, S, W, X, Y, and Z, each representing different fire resistance scenarios. However, the 2013 revision streamlined the standard by retaining only the most stringent categories: C, W, and Z. This simplification aimed to focus on the most critical aspects of fire resistance, ensuring that cables meet the highest safety standards.
BS 6387:2013 provided more detailed descriptions of the test procedures for each category, enhancing the reproducibility and reliability of the tests. These clarifications ensure consistent testing across different laboratories and manufacturers.
The 2013 revision of BS 6387 aimed to align more closely with international standards, such as IEC 60331, facilitating global applicability and acceptance. This alignment helps manufacturers and designers ensure compliance with both British and international fire safety requirements.
By focusing on the CWZ classification, BS 6387:2013 underscores the importance of cables that can withstand fire, water, and mechanical shocks simultaneously. This emphasis reflects a commitment to the highest level of safety in critical applications, such as emergency systems and life safety circuits.
The transition from BS 6387:1994 to BS 6387:2013 has several implications:
Manufacturers: Need to ensure that their products meet the updated CWZ classification requirements, which may involve redesigning cables or updating testing protocols.
Design Engineers: Must specify cables that comply with the latest standards, particularly for safety-critical applications.
Regulatory Bodies: Should update compliance and inspection procedures to reflect the changes in the standard.
The evolution from BS 6387:1994 to BS 6387:2013 represents a significant advancement in fire-resistant cable standards. By simplifying test categories, clarifying procedures, aligning with international standards, and emphasizing the CWZ classification, the 2013 revision enhances the reliability and safety of cables used in critical applications. Industry stakeholders must adapt to these changes to ensure compliance and maintain the highest safety standards.
To explore certified BS 6387 CWZ fire resistant cables for your project, visit our product page: Fire Resistant Cables