Integrated 9/11/18/20 Cores 0.75mmsq UIC Databus Cables
APPLICATIONThe BRAIL UIC railway vehicle data bus cable is specifically designed for the transmission of digital signals within railway vehicles, providing reliable and stable data communication in harsh railway operating environments.CONSTRUCTIONFor …
71Integrated 9_11_18_20 Cores 0.75mmsq UIC Databus Cables.pdf Contact us

APPLICATION

The BRAIL UIC railway vehicle data bus cable is specifically designed for the transmission of digital signals within railway vehicles, providing reliable and stable data communication in harsh railway operating environments.

CONSTRUCTION

For 9 cores UIC databus cables :

4 cores10 mm² stranded tinned copper conductor with LSZH insulation.
Combined Element3 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm²) are twisted with a filling element to a combined element.
Core WrappingOverlapped plastic-foil(s)
Elements sheathsTPE
UIC Data Bus 0.75mm²Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to a pair.
Core WrappingOverlapped plastic-foil(s)
ScreenTin plated copper braid
Elements sheathsTPE
Core WrappingOverlapped plastic-foil(s)
Stranding4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers
Core WrappingOverlapped plastic-foil(s)
Outer SheathCross-linked oil resistant LSZH compound

For 11 cores UIC databus cables :

4 cores10 mm² stranded tinned copper conductor with LSZH insulation
Combined Element5 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm² and 2 x 1.0 mm²) are twisted with a filling element to form a combined element.
Core WrappingOverlapped plastic-foil(s)
Elements sheathsTPE
UIC Data Bus 0.75mm²Two foam PE or foam skin insulated tinned copper r stranded conductors are twisted together with two filling elements to a pair
Core WrappingOverlapped plastic-foil(s)
ScreenTin plated copper braid
Elements sheathsTPE
Core WrappingOverlapped plastic-foil(s)
Stranding4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers
Core WrappingOverlapped plastic-foil(s)
Outer SheathCross-linked oil resistant LSZH compound

For 18/20 cores UIC databus cables :

Star QuadFour LSZH insulated 1mm² stranded tinned copper conductors are twisted to form a star quad
UIC Data Bus 0.75mm²Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to form a pair
Core WrappingOverlapped plastic-foil(s)
ScreenTin plated copper braid
Elements sheathsTPE
Core WrappingOverlapped plastic-foil(s)
Stranding4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers
Core WrappingOverlapped plastic-foil(s)
ScreenTin plated copper braid
Outer SheathCross-linked oil resistant LSZH compound

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300V
Maximum Temperature90°C
Minimum Temperature-40°C
Bending Radius12 x Overall Diameter

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

FRL-UIC-4G10+2G6+1G2.5+2G0.75

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Sheath ThicknessNominal Overall DiameterNominal WeightMax. Conductor ResistanceImpedanceMax. Attenuation
20°C@0.75-3MHz@1MHz@1.5MHz@2MHz@3MHz
mm²No/mmmmmmkg/kmΩ/kmΩdB/kmdB/kmdB/kmdB/km
0.7519/0.221.82591726.7120+/-1210131418
1080/0.41.95-----
684/0.33.39-----
2.537/0.298.21-----

FRL-UIC-4G10+2G6+1G2.5+2G1+2G0.75

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Sheath ThicknessNominal Overall DiameterNominal WeightMax. Conductor ResistanceImpedanceMax. Attenuation
20°C@0.75-3MHz@1MHz@1.5MHz@2MHz@3MHz
mm²No/mmmmmmkg/kmΩ/kmΩdB/kmdB/kmdB/kmdB/km
0.7519/0.221.82596926.7120+/-1210131418
1080/0.41.95-----
684/0.33.39-----
2.537/0.298.21-----

FRL-UIC-4Q1S+2G0.75

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Sheath ThicknessNominal Overall DiameterNominal WeightMax. Conductor ResistanceImpedanceMax. Attenuation
20°C@0.75-3MHz@1MHz@1.5MHz@2MHz@3MHz
mm²No/mmmmmmkg/kmΩ/kmΩdB/kmdB/kmdB/kmdB/km
0.7519/0.221.818.549826.7120+/-1210131418
119/0.2520-----

FRL-UIC-4Q1S+2P0.75S

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Sheath ThicknessNominal Overall DiameterNominal WeightMax. Conductor ResistanceImpedanceMax. Attenuation
20°C@0.75-3MHz@1MHz@1.5MHz@2MHz@3MHz
mm²No/mmmmmmkg/kmΩ/kmΩdB/kmdB/kmdB/kmdB/km
0.7519/0.221.52353026.7120+/-1210131418
119/0.2520-----