The BRAIL UIC railway vehicle data bus cable is specifically designed for the transmission of digital signals within railway vehicles, providing reliable and stable data communication in harsh railway operating environments.
4 cores | 10 mm² stranded tinned copper conductor with LSZH insulation. |
Combined Element | 3 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm²) are twisted with a filling element to a combined element. |
Core Wrapping | Overlapped plastic-foil(s) |
Elements sheaths | TPE |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to a pair. |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Outer Sheath | Cross-linked oil resistant LSZH compound |
4 cores | 10 mm² stranded tinned copper conductor with LSZH insulation |
Combined Element | 5 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm² and 2 x 1.0 mm²) are twisted with a filling element to form a combined element. |
Core Wrapping | Overlapped plastic-foil(s) |
Elements sheaths | TPE |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper r stranded conductors are twisted together with two filling elements to a pair |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Outer Sheath | Cross-linked oil resistant LSZH compound |
Star Quad | Four LSZH insulated 1mm² stranded tinned copper conductors are twisted to form a star quad |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to form a pair |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Outer Sheath | Cross-linked oil resistant LSZH compound |
Nominal Voltage | 300V |
Maximum Temperature | 90°C |
Minimum Temperature | -40°C |
Bending Radius | 12 x Overall Diameter |
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
EN 50306-2 | Hazard levels HL1, HL2, HL3 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 |
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 917 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 969 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 18.5 | 498 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.5 | 23 | 530 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |