APPLICATION
Our BRAIL Cat5E series data cables are specifically designed for rail transit environments and are suitable for internal and external fixed connection applications in trains, subways, buses, and other types of vehicles. This series of cables is particularly well-suited for applications requiring high network performance. Specially designed, they offer superior interference resistance and environmental adaptability, ensuring long-term stable operation in complex rail transit environments.
CONSTRUCTION
For 4 x 0.5mm², 4 x 22AWG cables :
Conductors | Stranded tin plated copper conductor (for 0.5mm² cables) or stranded silver plated copper conductor (for 22AWG cables) according to IEC 60228 class 5. |
Insulation | PE. |
Cable Element | Individual conductor stranded together. |
EMC Screen1 | Plastic laminated aluminium-tape. |
EMC Screen2 | Tin plated copper braid. |
Core Wrapping | Plastic tape(s). |
Outer Sheath | Electron beam crosslinkable compound. |
For 4 x 2 x 22AWG cables :
Center | PE filler. |
4 pairs 2 x 22AWG | Stranded tin plated copper conductor according to IEC 60228 class 5. |
Insulation | PE. |
EMC Screen1 | Plastic laminated aluminium-tape. |
EMC Screen2 | Tin plated copper braid. |
Core Wrapping | Plastic tape(s). |
Outer Sheath | Electron beam crosslinkable compound. |
ELECTRICAL & MECHANICAL PROPERTIES
Nominal Voltage | 300V |
Max. Temperature | 90°C |
Min. Temperature | -40°C |
Bending Radius | 6 x Overall Diameter |
CHEMICAL & ENVIRONMENTAL PROPERTIE
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION
EN 50306-2 | Hazard levels HL1, HL2, HL3 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 |
FIRE PERFORMANCE IN GENERAL
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-CAT5E-4C0.5S
Nominal Cross Sectional Area | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Max. Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Max. Capacitance |
---|
20°C | @100MHz | f≤30MHz | core to core | Core to screen |
---|
mm² | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
---|
0.5 | 1.2 | 8.3 | 102 | 40.1 | 1.1 | 100+/-5 | 200 | 65 | 100 |
FRL-CAT5E-4C22A
Nominal Cross Sectional Area | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Max. Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Max. Capacitance |
---|
20°C | @100MHz | f≤30MHz | core to core | Core to screen |
---|
AWG | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
---|
22 | 1.2 | 7.25 | 81 | 54.4 | 1.1 | 100+/-5 | 200 | 65 | 100 |
FRL-CAT5E-4P22A
Nominal Cross Sectional Area | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Max. Resistance Unbalance | Characteristic Impedance | Transfer Impedance | Max. Capacitance |
---|
20°C | @100MHz | f≤30MHz | core to core | Core to screen |
---|
AWG | mm | mm | kg/km | Ω/km | Ω/km | Ω | mΩ/m | pF/m | pF/m |
---|
22 | 1.2 | 12.6 | 174 | 54.4 | 1.1 | 100+/-5 | 200 | 65 | 100 |