CV / CVZ Indoor Equipment Cables
APPLICATIONThe cables are used as cabling wires for the relays and electronic equipments in the Traffic Control Center and Trackside Equipment Shelter. The CV cables are suitable for use only in Optical Control Panel (OCP) wiring.STANDARDSNCF CT 500CA…
CV CVZ Indoor Equipment Cables.pdf Contact us

APPLICATION

The cables are used as cabling wires for the relays and electronic equipments in the Traffic Control Center and Trackside Equipment Shelter. The CV cables are suitable for use only in Optical Control Panel (OCP) wiring.

STANDARD

  • SNCF CT 500

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Class 5 stranded tinned copper (for flexible wires CV-S & CVZ-S type), class 1 solid tinned copper (for stiff wires CV & CVZ), 0.5/1.0/2.5/6.0 mm cross section.

  • Insulation: White (for CVZ type)/coloured (for CV type) unleaded PVC.

  • Sheath: Coloured polyamide outer sheath (for CVZ & CVZ-S type).

CV/CVZ

Nominal Conductor Diametermm0.81.171.78
Nominal Cross Section Areamm0.51.02.5
Maximum Conductor Resistance(DC)Ω/km36.117.97.56
Operating VoltageV750

CV-S/CVZ-S

No of Strands/ Strand DiameterNo/mm16/0.232/0.250/0.2584/0.3
Nominal Cross Section Areamm0.51.02.56
Maximum Conductor Resistance (DC)Ω/km40.120.08.213.39
Operating VoltageV750

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius (static): 4×OD (for fl exible wire); 5×OD (for stiff wire)

  • Minimum Bending Radius (dynamic): 8×OD (for fl exible wire); 10×OD (for stiff wire)

  • Operating Temperature: -15℃ to +70℃

DIMENSIONS AND WEIGHT

CV/CVZ Cables

Cable CodeNumber of ConductorsNominal Sheath Thickness mmNominal Overall Diameter mmNominal Weight kg/km

0.8mm Conductor, 1.6mm Insulated Wire
BRAIL CV-075-Y-1C0.5S1--6

1.17mm Conductor, 1.9mm Insulated Wire
BRAIL CVZ-075-Y(4Y)-1C1S10.22.313.2

1.78mm Conductor, 2.7mm Insulated Wire
BRAIL CVZ-075-Y(4Y)- 1C2.5S10.23.129.3

CV-S/CVZ-S Cables

Cable CodeNumber of ConductorsNominal Sheath Thickness mmNominal Overall Diameter mmNominal Weight kg/km

16/0.2mm Conductor, 1.6mm Insulated Wire
BRAIL CV-S-075-Y-1C0.5S1--6.8
BRAIL CVZ-S-075-Y-1C0.5S10.352.37.6

32/0.2mm Conductor, 2.1mm Insulated Wire
BRAIL CVZ-S-075-Y(4Y)-1C1S10.22.513.5
BRAIL  CVZ-S-075-Y(4Y)-1P1S1P0.22.528.2

50/0.25mm Conductor, 3.0mm Insulated Wire
BRAIL CVZ-S-075-Y(4Y)- 1G2.510.23.429.3

84/0.3mm Conductor, 4.2mm Insulated Wire
BRAIL CVZ-S-075- Y(4Y)-1G610.24.660.1