ZUG/ ZUT/ SUG Indoor Equipment Cables
APPLICATIONThe cables are used as cabling for the relays and electronic equipments in the Traffic Control Center and Trackside Equipment Shelter. The cables are suitable for indoor interconnection of railway network equipments.STANDARDSNCF CT 455CABLE…
ZUG ZUT SUG Indoor Equipment Cables.pdf Contact us

APPLICATION

The cables are used as cabling for the relays and electronic equipments in the Traffic Control Center and Trackside Equipment Shelter. The cables are suitable for indoor interconnection of railway network equipments.

STANDARD

  • SNCF CT 455

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Conductors: Class 5 stranded tinned copper, 1 mm or 0.38 mm cross section.

  • Insulation: Coloured PVC.

  • Cabling Element: Pairs (for ZUG/ZUT)/Cores (for SUG).

  • Core Wrapping (optional): Plastic tape(s) with overlapping.

  • Screen (optional): Tinned copper braid for electrostatic protection (only for ZUT type).

  • Sheath: Black FRPVC compound. LSZH option can be offered upon request.

No of Strands/ Strand DiameterNo/mm12/0.232/0.2
Nominal Cross Section Areamm0.381
Maximum Conductor Resistance (DC)Ω/km52.520.1
Operating VoltageV450/750450/750

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 4×OD (static); 8×OD (dynamic)

  • Operating Temperature: -15℃ to +70℃

DIMENSIONS AND WEIGHT

ZUG Cables

Cable CodeNumber of PairsNominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
12/0.2mm Conductor, 1.4mm Insulated Wire
BRAIL  ZUG-075-YY-28P0.38S280.715.7310
32/0.2mm Conductor, 2.09mm Insulated Wire
BRAIL  ZUG-075-YY-1P1S10.77.059
BRAIL  ZUG-075-YY-3P1S30.79.9108
BRAIL  ZUG-075-YY-6P1S60.712.4184
BRAIL  ZUG-075-YY-12P1S120.715.7335

SUG Cables

Cable CodeNumber of ConductorsNominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
32/0.2mm Conductor, 2.09mm Insulated Wire
BRAIL  SUG-075-YY-3C1S30.7873

ZUT Cables

Cable CodeNumber of PairsNominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
32/0.2mm Conductor, 2.09mm Insulated Wire
BRAIL  ZUT-075-YCY-2P1S20.79.5122
BRAIL  ZUT-075-YCY-6P1S60.713.5276
BRAIL  ZUT-075-YCY-12P1S120.717.5445