CCPSSP-FR0.3 n×1×1.4
APPLICATIONThe cables are used as railway cables and can be installed directly into the ground or in ducts.STANDARDRENFE E.T. 03.365.051.6CABLE CONSTRUCTIONElectrical Characteristics at 20℃Conductors: Soft annealed solid copper, 1.4 mm nominal diamet…
CCPSSP-FR0.3 nx1x1.4.pdf Contact us

APPLICATION

The cables are used as railway cables and can be installed directly into the ground or in ducts.

STANDARD

  • RENFE E.T. 03.365.051.6

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.

  • Insulation: PE insulation.

  • Stranding: Cores are helically stranded in concentric layers.

  • Core Wrapping: Two or more layers of plastic tape(s) with overlapping.

  • Screen: Copper tapes with overlap (protection against interference).

  • Inner Sheath: PE sheath.

  • Armour: Two layers of steel tape (0.8mm thick).

  • Outer Sheath: PE sheath.

Nominal Conductor Diametermm1.4
Maximum Conductor ResistanceΩ/km11.9
Minimum Insulation Resistance @500 V DCMΩ.km15000
Resistance Unbalance%2
Test Voltage @50Hz 1min

Core to CoreVeff2100
Core to ScreenVeff2500
Reduction Factor @100V/km 50Hz
0.3

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 10×OD

  • Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNumber of
Cores
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
InnerOuter
1.4mm Conductor, 2.6mm Insulated Wire
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-2C1.421.51.616.5530
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-4C1.441.51.617.5608
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-7C1.471.51.619.0718
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-9C1.491.51.622.7914
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-12C1.4121.51.623.2977
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-19C1.4191.61.825.21185
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-27C1.4271.61.828.11437
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-37C1.4371.71.831.41754
BRAIL CCPSSP-FR0.3-2Y(K)2YB2Y-48C1.4481.71.834.22062